{"product_id":"solaredge-40000-w-three-phase-inverter","title":"SolarEdge 40000 W Three Phase Inverter","description":"\u003cp\u003e\u003cspan\u003eMaximize energy production, safety, and achieve significant savings in Balance of System (BoS) and Operations and Maintenance (O\u0026amp;M) costs with our range of innovative and lightweight three phase inverters. Our three phase ground mount, rooftop, carport inverters are ideal for driving more power and more safety into broad range of commercial projects: Deliver up to 10% more energy by pairing with our Power Optimizers, Reduce BoS costs by 50% with longer strings and flexible design, Maximize system uptime: pinpoint issues with module-level monitoring, Instill confidence with advanced safety, such as arc fault protection and rapid shutdown, There's a reason why 50% of Fortune 100 companies have SolarEdge on their roofs. Ensuring peace of mind is no problem with our built-in advanced SafeDC™ features, including: Fully integrated rapid shutdown, Arc-fault detection \u0026amp; prevention, Surge protection. Get more done in less time - and minimize Operations \u0026amp; Maintenance (O\u0026amp;M)costs - with innovative, flexible design: Reduce time, cost and labor with a simple 2-person installation through lightweight, modular design. Synergy Manager unit provides easy access for DC disconnect during maintenance. Higher system uptime with independently working Synergy Unit. Supports 3-wire connection and accommodates no-neutral or delta configurations.\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUp to 175% oversizing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOnly 70.5 lbs. means a simpler install\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustry-Leading, extendable 12-year warranty, extendable to 25 years\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFully integrated rapid shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eArc-fault detection \u0026amp; prevention\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSurge protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpecifically designed to work with power optimizers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuick and easy inverter commissioning directly from a smartphone using SolarEdge SetApp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFixed voltage inverter for superior efficiency and longer strings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in type 2 DC and AC Surge Protection, to better withstand lightning events\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmall, lightest in its class, and easy to install outdoors or indoors on provided bracket\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated arc fault protection and rapid shutdown for NEC 2014, 2017, and 2020, per article 690.11 and 690.12\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in module-level monitoring with Ethernet, wireless or cellular communication for full system visibility\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated Safety Switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUL1741 SA and SB certified, for CPUC Rule 21 grid compliance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eThree phase inverters for the 120\/208V grid\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"42\" data-end=\"64\"\u003e\n\u003cstrong data-start=\"44\" data-end=\"54\"\u003eWidth:\u003c\/strong\u003e 12.5 in\u003c\/li\u003e\n\u003cli data-start=\"65\" data-end=\"88\"\u003e\n\u003cstrong data-start=\"67\" data-end=\"78\"\u003eHeight:\u003c\/strong\u003e 31.8 in\u003c\/li\u003e\n\u003cli data-start=\"89\" data-end=\"111\"\u003e\n\u003cstrong data-start=\"91\" data-end=\"101\"\u003eDepth:\u003c\/strong\u003e 11.8 in\u003c\/li\u003e\n\u003cli data-start=\"112\" data-end=\"155\"\u003e\n\u003cstrong data-start=\"114\" data-end=\"140\"\u003eMaximum Input Voltage:\u003c\/strong\u003e 840-1000 VDC\u003c\/li\u003e\n\u003cli data-start=\"156\" data-end=\"204\"\u003e\n\u003cstrong data-start=\"158\" data-end=\"191\"\u003eTransformer-Less, Ungrounded:\u003c\/strong\u003e Yes, Input\u003c\/li\u003e\n\u003cli data-start=\"205\" data-end=\"252\"\u003e\n\u003cstrong data-start=\"207\" data-end=\"239\"\u003eReverse-Polarity Protection:\u003c\/strong\u003e Yes, Input\u003c\/li\u003e\n\u003cli data-start=\"253\" data-end=\"323\"\u003e\n\u003cstrong data-start=\"255\" data-end=\"292\"\u003eGround Fault Isolation Detection:\u003c\/strong\u003e 167 kOhm Sensitivity (Input)\u003c\/li\u003e\n\u003cli data-start=\"324\" data-end=\"373\"\u003e\n\u003cstrong data-start=\"326\" data-end=\"366\"\u003eMaximum Input Short-Circuit Current:\u003c\/strong\u003e 55 A\u003c\/li\u003e\n\u003cli data-start=\"374\" data-end=\"418\"\u003e\n\u003cstrong data-start=\"376\" data-end=\"404\"\u003eCEC Weighted Efficiency:\u003c\/strong\u003e 98.5% Input\u003c\/li\u003e\n\u003cli data-start=\"419\" data-end=\"457\"\u003e\n\u003cstrong data-start=\"421\" data-end=\"447\"\u003eRated AC Output Power:\u003c\/strong\u003e 40000 W\u003c\/li\u003e\n\u003cli data-start=\"458\" data-end=\"498\"\u003e\n\u003cstrong data-start=\"460\" data-end=\"488\"\u003eMaximum AC Power Output:\u003c\/strong\u003e 40000 W\u003c\/li\u003e\n\u003cli data-start=\"499\" data-end=\"565\"\u003e\n\u003cstrong data-start=\"501\" data-end=\"538\"\u003eAC Frequency Range (Min-Nom-Max):\u003c\/strong\u003e 59.3-60-60.5 Hz (Output)\u003c\/li\u003e\n\u003cli data-start=\"566\" data-end=\"598\"\u003e\n\u003cstrong data-start=\"568\" data-end=\"587\"\u003eGFDI Threshold:\u003c\/strong\u003e 1 Output\u003c\/li\u003e\n\u003cli data-start=\"599\" data-end=\"661\"\u003e\n\u003cstrong data-start=\"601\" data-end=\"637\"\u003eTotal Harmonic Distortion (THD):\u003c\/strong\u003e +\/-0.85 to 1 (Output)\u003c\/li\u003e\n\u003cli data-start=\"662\" data-end=\"756\"\u003e\n\u003cstrong data-start=\"664\" data-end=\"742\"\u003eUtility Monitoring, Islanding Protection, Country Configurable Thresholds:\u003c\/strong\u003e Yes, Output\u003c\/li\u003e\n\u003cli data-start=\"757\" data-end=\"812\"\u003e\n\u003cstrong data-start=\"759\" data-end=\"799\"\u003eTypical Nighttime Power Consumption:\u003c\/strong\u003e \u0026lt;4 W Input\u003c\/li\u003e\n\u003cli data-start=\"813\" data-end=\"881\"\u003e\n\u003cstrong data-start=\"815\" data-end=\"861\"\u003eAC L-L Output Voltage Range (Min-Nom-Max):\u003c\/strong\u003e 422.5-480-529 VAC\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"948\"\u003e\n\u003cstrong data-start=\"884\" data-end=\"930\"\u003eAC L-N Output Voltage Range (Min-Nom-Max):\u003c\/strong\u003e 244-277-305 VAC\u003c\/li\u003e\n\u003cli data-start=\"949\" data-end=\"1002\"\u003e\n\u003cstrong data-start=\"951\" data-end=\"985\"\u003eMaximum DC Power (Module STC):\u003c\/strong\u003e 700000 W Input\u003c\/li\u003e\n\u003cli data-start=\"1003\" data-end=\"1067\"\u003e\n\u003cstrong data-start=\"1005\" data-end=\"1047\"\u003eContinuous Output Current (Per Phase):\u003c\/strong\u003e 48.25 A AC Output\u003c\/li\u003e\n\u003cli data-start=\"1068\" data-end=\"1106\"\u003e\n\u003cstrong data-start=\"1070\" data-end=\"1096\"\u003eMaximum Input Current:\u003c\/strong\u003e 48.25 A\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1170\"\u003e\n\u003cstrong data-start=\"1109\" data-end=\"1148\"\u003eSupported Communication Interfaces:\u003c\/strong\u003e 2 x RS485, Ethernet\u003c\/li\u003e\n\u003cli data-start=\"1171\" data-end=\"1292\"\u003e\n\u003cstrong data-start=\"1173\" data-end=\"1200\"\u003eInverter Commissioning:\u003c\/strong\u003e With the SetApp Mobile Application using built-in Wi-Fi Access Point for Local Connection\u003c\/li\u003e\n\u003cli data-start=\"1293\" data-end=\"1366\"\u003e\n\u003cstrong data-start=\"1295\" data-end=\"1314\"\u003eRapid Shutdown:\u003c\/strong\u003e NEC 2014-2023 per articles 690.11 and 690.12: Yes\u003c\/li\u003e\n\u003cli data-start=\"1367\" data-end=\"1429\"\u003e\n\u003cstrong data-start=\"1369\" data-end=\"1406\"\u003eAC Output Conduit Size\/AWG Range:\u003c\/strong\u003e 3\/4 in\/1 in\/6-10 AWG\u003c\/li\u003e\n\u003cli data-start=\"1430\" data-end=\"1494\"\u003e\n\u003cstrong data-start=\"1432\" data-end=\"1468\"\u003eDC Input Conduit Size\/AWG Range:\u003c\/strong\u003e 3\/4 in or 1 in\/6-10 AWG\u003c\/li\u003e\n\u003cli data-start=\"1495\" data-end=\"1511\"\u003e\n\u003cstrong data-start=\"1497\" data-end=\"1507\"\u003ePhase:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli data-start=\"1512\" data-end=\"1541\"\u003e\n\u003cstrong data-start=\"1514\" data-end=\"1531\"\u003eNoise Rating:\u003c\/strong\u003e \u0026lt;62 dBA\u003c\/li\u003e\n\u003cli data-start=\"1542\" data-end=\"1582\"\u003e\n\u003cstrong data-start=\"1544\" data-end=\"1556\"\u003eCooling:\u003c\/strong\u003e Fans (User Replaceable)\u003c\/li\u003e\n\u003cli data-start=\"1583\" data-end=\"1631\"\u003e\n\u003cstrong data-start=\"1585\" data-end=\"1620\"\u003eRS485 Surge Protection Plug-in:\u003c\/strong\u003e Built-In\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1672\"\u003e\n\u003cstrong data-start=\"1634\" data-end=\"1661\"\u003eAC\/DC Surge Protection:\u003c\/strong\u003e Built-In\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1719\"\u003e\n\u003cstrong data-start=\"1675\" data-end=\"1702\"\u003eDC Fuses (Single Pole):\u003c\/strong\u003e 25 A, Built-In\u003c\/li\u003e\n\u003cli data-start=\"1720\" data-end=\"1770\"\u003e\n\u003cstrong data-start=\"1722\" data-end=\"1750\"\u003eSmart Energy Management:\u003c\/strong\u003e Export Limitation\u003c\/li\u003e\n\u003cli data-start=\"1771\" data-end=\"1804\"\u003e\n\u003cstrong data-start=\"1773\" data-end=\"1791\"\u003eDC Disconnect:\u003c\/strong\u003e Integrated\u003c\/li\u003e\n\u003cli data-start=\"1805\" data-end=\"1841\"\u003e\n\u003cstrong data-start=\"1807\" data-end=\"1837\"\u003eNumber of DC Inputs Pairs:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli data-start=\"1842\" data-end=\"1872\"\u003e\n\u003cstrong data-start=\"1844\" data-end=\"1862\"\u003eMounting Type:\u003c\/strong\u003e Bracket\u003c\/li\u003e\n\u003cli data-start=\"1873\" data-end=\"1916\"\u003e\n\u003cstrong data-start=\"1875\" data-end=\"1901\"\u003eOperating Temperature:\u003c\/strong\u003e -40 to 140°F\u003c\/li\u003e\n\u003cli data-start=\"1917\" data-end=\"1951\"\u003e\n\u003cstrong data-start=\"1919\" data-end=\"1941\"\u003eProtection Rating:\u003c\/strong\u003e NEMA 3R\u003c\/li\u003e\n\u003cli data-start=\"1952\" data-end=\"2125\"\u003e\n\u003cstrong data-start=\"1954\" data-end=\"1968\"\u003eStandards:\u003c\/strong\u003e UL1741, UL1741 SA, UL1741 SB, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07, IEEE1547-2018, Rule 21, Rule 14 (HI), FCC part15 class A, CSAcUS\u003c\/li\u003e\n\u003cli data-start=\"2126\" data-end=\"2155\"\u003e\n\u003cstrong data-start=\"2128\" data-end=\"2141\"\u003eWarranty:\u003c\/strong\u003e 12-20 Years\u003c\/li\u003e\n\u003cli data-start=\"2156\" data-end=\"2179\"\u003e\n\u003cstrong data-start=\"2158\" data-end=\"2169\"\u003eWeight:\u003c\/strong\u003e 78.2 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDocuments \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0); font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/drive.google.com\/file\/d\/1GTm4AK73gl8TTsEf7D6AzNGjj-ppylIC\/view?usp=sharing\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eSpecification Sheet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0); font-weight: bold;\"\u003e\u003ca href=\"https:\/\/drive.google.com\/file\/d\/1S15pFY66VeA5Mtvi0xdPBk9SitJFiLDC\/view?usp=sharing\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eWarranty Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0); font-weight: bold;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/store.solarcellzusa.com\/Item%20Documents\/SE17.3K-USR2IBNZ4_Installation%20Guide.pdf\" style=\"color: rgb(255, 42, 0);\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Green Efficients Distro","offers":[{"title":"Default Title","offer_id":47210706469047,"sku":null,"price":3599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0740\/8078\/0471\/files\/SE40K-USR8IBNZ4_01.webp?v=1774729112","url":"https:\/\/greenefficientdistro.com\/products\/solaredge-40000-w-three-phase-inverter","provider":"Green Efficients Distro","version":"1.0","type":"link"}