{"product_id":"fronius-symo-advanced-15-kw-peak-three-phase-commercial-string-inverter","title":"15kW Fronius 4,210,092,801 SYMO Advanced 15.0-3 480VAC Inverter","description":"\u003ch2 id=\"tinymce_scroll_sign\"\u003eDiscover the Fronius Symo Advanced Inverter\u003c\/h2\u003e\n\u003cp\u003eFurther developed with safety in mind: the Fronius Symo Advanced opens the next chapter in the Fronius SnapINverter portfolio. The inverter combines proven performance with new safety technology, making the Fronius Symo Advanced the future-proof choice for commercial photovoltaic systems of all sizes. The latest generation of the inverter with power categories ranging from 10 to 20 kW impresses with reliable arc protection through the new Fronius Arc Guard technology, SuperFlex Design for absolute freedom in roof planning and maximum yields through the Dynamic Peak Manager. Featuring ten models ranging from 10 kW to 24 kW, the Fronius Symo Advanced is the ideal inverter for commercial applications. The new Advanced versions combine the benefits of the Fronius Symo with additional value for states with Module Level Shutdown requirements including integrated PLC transmitter for SunSpec Rapid Shutdown communication standard, compliance with NEC pre-2014, 2014 and 2017, zero tilt mounting, light weight and field serviceability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePC board replacement process\u003c\/li\u003e\n\u003cli\u003eSnapINverter mounting system\u003c\/li\u003e\n\u003cli\u003eDesign Flexibility\u003c\/li\u003e\n\u003cli\u003eIntegrated data communication - We are the first inverter manufacturer to offer a data communication package with fully integrated datalogging, WLAN, Ethernet, energy management, web server and a range of interfaces. The inverter is connected to the internet by network cable or WLAN - without additional cabling - and grants you the perfect overview of how the PV system is operating. Connection to third-party components is provided by means of interfaces such as Modbus TCP SunSpec, Modbus RTU SunSpec or Fronius Solar API (JSON). The open interfaces can also be operated in parallel to the Fronius Solar. Web\u003c\/li\u003e\n\u003cli\u003eSuperFlex Design - The Fronius SuperFlex Design is an ingenious combination of technical performance attributes that make designing your PV system not only extremely simple, but also incredibly flexible. The key performance factors of the SuperFlex Design are two MPP trackers, together with a high system voltage and wide DC input voltage range. Every DC input, and therefore every MPP tracker, is able to accommodate the entire nominal output of the inverter. Regardless of whether the inverter has to cope with different roof orientations, shading of one or two strings, or the use of residual modules: a Fronius inverter featuring integrated SuperFlex Design will satisfy every conceivable operational PV system planning scenario using just a single inverter model\u003c\/li\u003e\n\u003cli\u003eSmart Grid Ready - Fronius inverters are ready for the Smart Grid of tomorrow. The inverters are optimally equipped to meet the technical requirements of grids in the future. A series of smart functions, known as Advanced Grid Features, are built into the devices. They include a number of control functions for optimum feed-in of reactive power and effective power. These functions are designed to enable stable grid operation even when the PV system density is very high and to prevent unwanted interruptions to feed-in and associated yield losses if grid parameters exceed the thresholds. Fronius inverters therefore help to guarantee the yield of a PV system. Furthermore, where feed-in limits are imposed, Fronius inverters can provide dynamic feed-in control with self-consumption taken into account. Just connect the meter and set the feed-in limit\u003c\/li\u003e\n\u003cli\u003ePower Line Communication\u003c\/li\u003e\n\u003cli\u003eUSB (A socket) - Datalogging and inverter update possible via USB, 2x RS422 (RJ45 socket) - Fronius Solar Net, interface protocol, Power Line Communication (PLC) Yes - SunSpec Rapid Shutdown communication standard\u003c\/li\u003e\n\u003cli\u003eAdmissible conductor size DC - AWG 14-AWG 6 copper direct, AWG 6 aluminum direct, AWG 4-AWG 2 copper or aluminum with input combiner\u003c\/li\u003e\n\u003cli\u003eAdmissible conductor size AC - AWG 14 - AWG 6\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"0\" data-end=\"22\"\u003e\n\u003cstrong data-start=\"2\" data-end=\"12\"\u003eWidth:\u003c\/strong\u003e 28.5 in\u003c\/li\u003e\n\u003cli data-start=\"23\" data-end=\"46\"\u003e\n\u003cstrong data-start=\"25\" data-end=\"36\"\u003eHeight:\u003c\/strong\u003e 20.1 in\u003c\/li\u003e\n\u003cli data-start=\"47\" data-end=\"68\"\u003e\n\u003cstrong data-start=\"49\" data-end=\"59\"\u003eDepth:\u003c\/strong\u003e 8.9 in\u003c\/li\u003e\n\u003cli data-start=\"69\" data-end=\"115\"\u003e\n\u003cstrong data-start=\"71\" data-end=\"102\"\u003eRecommended PV Power (kWp):\u003c\/strong\u003e 15 kW Peak\u003c\/li\u003e\n\u003cli data-start=\"116\" data-end=\"179\"\u003e\n\u003cstrong data-start=\"118\" data-end=\"167\"\u003eMaximum Usable Input Current (MPPT 1\/MPPT 2):\u003c\/strong\u003e 25\/16.5 A\u003c\/li\u003e\n\u003cli data-start=\"180\" data-end=\"261\"\u003e\n\u003cstrong data-start=\"182\" data-end=\"247\"\u003eMaximum Array Short-Circuit Current (1.5 lmax) (MPPT1\/MPPT2):\u003c\/strong\u003e 37.5\/24.8 A\u003c\/li\u003e\n\u003cli data-start=\"262\" data-end=\"324\"\u003e\n\u003cstrong data-start=\"264\" data-end=\"290\"\u003eNominal Input Voltage:\u003c\/strong\u003e 350 V at 208 V \/ 370 V at 240 V\u003c\/li\u003e\n\u003cli data-start=\"325\" data-end=\"386\"\u003e\n\u003cstrong data-start=\"327\" data-end=\"374\"\u003eDC Input Voltage Range (Udc Min + Udc Max):\u003c\/strong\u003e 200-600 V\u003c\/li\u003e\n\u003cli data-start=\"387\" data-end=\"435\"\u003e\n\u003cstrong data-start=\"389\" data-end=\"427\"\u003eFeed-In-Start Voltage (Udc start):\u003c\/strong\u003e 200 V\u003c\/li\u003e\n\u003cli data-start=\"436\" data-end=\"472\"\u003e\n\u003cstrong data-start=\"438\" data-end=\"460\"\u003eMPP Voltage Range:\u003c\/strong\u003e 300-500 V\u003c\/li\u003e\n\u003cli data-start=\"473\" data-end=\"509\"\u003e\n\u003cstrong data-start=\"475\" data-end=\"501\"\u003eMaximum Input Voltage:\u003c\/strong\u003e 600 V\u003c\/li\u003e\n\u003cli data-start=\"510\" data-end=\"535\"\u003e\n\u003cstrong data-start=\"512\" data-end=\"531\"\u003eNumber of MPPT:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli data-start=\"536\" data-end=\"591\"\u003e\n\u003cstrong data-start=\"538\" data-end=\"569\"\u003eAC Nominal Output (P ac,r):\u003c\/strong\u003e 9995 W at 208\/240 V\u003c\/li\u003e\n\u003cli data-start=\"592\" data-end=\"657\"\u003e\n\u003cstrong data-start=\"594\" data-end=\"619\"\u003eMaximum Output Power:\u003c\/strong\u003e 9995 VA at 208 V \/ 9995 VA at 240 V\u003c\/li\u003e\n\u003cli data-start=\"658\" data-end=\"697\"\u003e\n\u003cstrong data-start=\"660\" data-end=\"685\"\u003eOutput Configuration:\u003c\/strong\u003e 208\/240 V\u003c\/li\u003e\n\u003cli data-start=\"698\" data-end=\"743\"\u003e\n\u003cstrong data-start=\"700\" data-end=\"732\"\u003eNominal Operating Frequency:\u003c\/strong\u003e 45-60 Hz\u003c\/li\u003e\n\u003cli data-start=\"744\" data-end=\"790\"\u003e\n\u003cstrong data-start=\"746\" data-end=\"782\"\u003eTotal Harmonic Distortion (THD):\u003c\/strong\u003e \u0026lt;1.5%\u003c\/li\u003e\n\u003cli data-start=\"791\" data-end=\"830\"\u003e\n\u003cstrong data-start=\"793\" data-end=\"816\"\u003ePower Factor Range:\u003c\/strong\u003e 0-1 Ind\/Cap\u003c\/li\u003e\n\u003cli data-start=\"831\" data-end=\"905\"\u003e\n\u003cstrong data-start=\"833\" data-end=\"871\"\u003eMaximum Continuous Output Current:\u003c\/strong\u003e 27.7 A at 208 V \/ 24 A at 240 V\u003c\/li\u003e\n\u003cli data-start=\"906\" data-end=\"964\"\u003e\n\u003cstrong data-start=\"908\" data-end=\"933\"\u003eOCPD\/AC Breaker Size:\u003c\/strong\u003e 35 A at 208 V, 30 A at 240 V\u003c\/li\u003e\n\u003cli data-start=\"965\" data-end=\"996\"\u003e\n\u003cstrong data-start=\"967\" data-end=\"990\"\u003eMaximum Efficiency:\u003c\/strong\u003e 97%\u003c\/li\u003e\n\u003cli data-start=\"997\" data-end=\"1026\"\u003e\n\u003cstrong data-start=\"999\" data-end=\"1018\"\u003eCEC Efficiency:\u003c\/strong\u003e 96.5%\u003c\/li\u003e\n\u003cli data-start=\"1027\" data-end=\"1060\"\u003e\n\u003cstrong data-start=\"1029\" data-end=\"1050\"\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 4X\u003c\/li\u003e\n\u003cli data-start=\"1061\" data-end=\"1097\"\u003e\n\u003cstrong data-start=\"1063\" data-end=\"1090\"\u003eNight Time Consumption:\u003c\/strong\u003e \u0026lt;1 W\u003c\/li\u003e\n\u003cli data-start=\"1098\" data-end=\"1140\"\u003e\n\u003cstrong data-start=\"1100\" data-end=\"1122\"\u003eInverter Topology:\u003c\/strong\u003e Transformerless\u003c\/li\u003e\n\u003cli data-start=\"1141\" data-end=\"1179\"\u003e\n\u003cstrong data-start=\"1143\" data-end=\"1155\"\u003eCooling:\u003c\/strong\u003e Regulated Air Cooling\u003c\/li\u003e\n\u003cli data-start=\"1180\" data-end=\"1250\"\u003e\n\u003cstrong data-start=\"1182\" data-end=\"1199\"\u003eInstallation:\u003c\/strong\u003e Indoor \u0026amp; Outdoor Installation, Tilt from 0 - 90°\u003c\/li\u003e\n\u003cli data-start=\"1251\" data-end=\"1294\"\u003e\n\u003cstrong data-start=\"1253\" data-end=\"1279\"\u003eOperating Temperature:\u003c\/strong\u003e -40 to 140°F\u003c\/li\u003e\n\u003cli data-start=\"1295\" data-end=\"1336\"\u003e\n\u003cstrong data-start=\"1297\" data-end=\"1310\"\u003eHumidity:\u003c\/strong\u003e 0-100% (Non-Condensing)\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1399\"\u003e\n\u003cstrong data-start=\"1339\" data-end=\"1353\"\u003eElevation:\u003c\/strong\u003e Maximum Input Voltage of 600 V up to 3400 m\u003c\/li\u003e\n\u003cli data-start=\"1400\" data-end=\"1535\"\u003e\n\u003cstrong data-start=\"1402\" data-end=\"1430\"\u003eDC Connection Terminals:\u003c\/strong\u003e 6x DC+ \u0026amp; 6x DC- Screw Terminals for Copper (Solid\/Stranded\/Fine Stranded) or Aluminum (Solid\/Stranded)\u003c\/li\u003e\n\u003cli data-start=\"1536\" data-end=\"1593\"\u003e\n\u003cstrong data-start=\"1538\" data-end=\"1566\"\u003eAC Connection Terminals:\u003c\/strong\u003e Screw Terminals 14-6 AWG\u003c\/li\u003e\n\u003cli data-start=\"1594\" data-end=\"1637\"\u003e\n\u003cstrong data-start=\"1596\" data-end=\"1631\"\u003eDC Reverse Polarity Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1638\" data-end=\"1665\"\u003e\n\u003cstrong data-start=\"1640\" data-end=\"1659\"\u003eAnti-Islanding:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1666\" data-end=\"1739\"\u003e\n\u003cstrong data-start=\"1668\" data-end=\"1700\"\u003eOver Temperature Protection:\u003c\/strong\u003e Output Power Derating\/Active Cooling\u003c\/li\u003e\n\u003cli data-start=\"1740\" data-end=\"1757\"\u003e\n\u003cstrong data-start=\"1742\" data-end=\"1751\"\u003eAFCI:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1758\" data-end=\"1796\"\u003e\n\u003cstrong data-start=\"1760\" data-end=\"1790\"\u003eRapid Shutdown Compliance:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1797\" data-end=\"1868\"\u003e\n\u003cstrong data-start=\"1799\" data-end=\"1862\"\u003eGround Fault Protection with Isolation Monitor Interrupter:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1869\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1871\" data-end=\"1889\"\u003eDC Disconnect:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1896\" data-end=\"1986\"\u003e\n\u003cstrong data-start=\"1898\" data-end=\"1913\"\u003eInterfaces:\u003c\/strong\u003e USB (A Socket), 2x RS422 (RJ45 Socket), Power Line Communication (PLC)\u003c\/li\u003e\n\u003cli data-start=\"1987\" data-end=\"2048\"\u003e\n\u003cstrong data-start=\"1989\" data-end=\"2002\"\u003eDIN Rail:\u003c\/strong\u003e 4.2 in Length x 3.5 in Width x 2.6 in Depth\u003c\/li\u003e\n\u003cli data-start=\"2049\" data-end=\"2458\"\u003e\n\u003cstrong data-start=\"2051\" data-end=\"2065\"\u003eStandards:\u003c\/strong\u003e\n\u003cul data-start=\"2070\" data-end=\"2458\"\u003e\n\u003cli data-start=\"2070\" data-end=\"2195\"\u003eUL 1741-2010 Second Edition (Incl. UL1741 Supplement SA 2016-09 for California Rule 21 \u0026amp; Hawaiian Electric Code Rule 14H)\u003c\/li\u003e\n\u003cli data-start=\"2198\" data-end=\"2259\"\u003eUL1998 (For Functions: AFCI, RCMU \u0026amp; Isolation Monitoring)\u003c\/li\u003e\n\u003cli data-start=\"2262\" data-end=\"2315\"\u003eIEEE 1547-2003, IEEE 1547a-2014, IEEE 1547.1-2003\u003c\/li\u003e\n\u003cli data-start=\"2318\" data-end=\"2357\"\u003eANSI\/IEEE C62.41, FCC Part 15 A \u0026amp; B\u003c\/li\u003e\n\u003cli data-start=\"2360\" data-end=\"2404\"\u003eNEC 2017 Article 690, C22.2 No. 107.1-16\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2458\"\u003eUL1699B Issue 2-2013, CSA TIL M-07 Issue 1-2013\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2459\" data-end=\"2485\"\u003e\n\u003cstrong data-start=\"2461\" data-end=\"2474\"\u003eWarranty:\u003c\/strong\u003e 10 Years\u003c\/li\u003e\n\u003cli data-start=\"2486\" data-end=\"2509\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"2488\" data-end=\"2499\"\u003eWeight:\u003c\/strong\u003e 41.7 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/drive.google.com\/file\/d\/1nUj6SPnmUK_c7yhOY8VTJ1WGTMEdvQfM\/view?usp=drive_link\" style=\"color: #ff2a00;\" rel=\"noopener\" target=\"_blank\"\u003eSpecification Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003ca href=\"https:\/\/drive.google.com\/file\/d\/1hG7S1Edp8-xkDLTEIe_20JgBUk-_MmBZ\/view?usp=drive_link\" style=\"color: #ff2a00;\" rel=\"noopener\" target=\"_blank\"\u003eInstruction\/Installation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUnmatched Performance and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFronius Symo Advanced\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e15 kW peak inverter is engineered for reliable performance in commercial environments. With advanced technology, it optimally converts solar energy into usable electricity, ensuring minimal energy loss. This inverter not only supports three-phase systems but also provides superior efficiency, which is crucial for businesses looking to power operations sustainably. Because of its robust design, it withstands various environmental conditions, making it a dependable choice for long-term use.\u003c\/p\u003e\n\u003ch3\u003eSmart Features for Enhanced Control\u003c\/h3\u003e\n\u003cp\u003eEquipped with smart features, the Fronius Symo Advanced provides real-time monitoring and management capabilities. You can easily track energy production and consumption via a user-friendly interface, allowing for better energy management and cost savings. Furthermore, this inverter is compatible with solar storage systems, so businesses can utilize excess energy for later use. This flexibility offers a significant advantage, particularly for operations that require continuous power supply.\u003c\/p\u003e\n\u003ch3\u003eSimple Installation and Maintenance\u003c\/h3\u003e\n\u003cp\u003eInstallation of the \u003cstrong\u003eFronius Symo Advanced\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eis straightforward due to its modular design, which simplifies the entire process. The inverter's lightweight structure allows for easier handling and mounting. Moreover, regular maintenance is effortless, aiding in prolonged inverter life. Because Fronius emphasizes durability and efficiency, this inverter is an investment that pays off through enhanced energy savings and reduced operating costs, making it ideal for any commercial setting.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fronius","offers":[{"title":"Default Title","offer_id":47568637755575,"sku":"FRO-SA-10-3-208240L","price":3379.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0740\/8078\/0471\/files\/FRO-SA-10-3-208240L_01.jpg?v=1776066858","url":"https:\/\/greenefficientdistro.com\/products\/fronius-symo-advanced-15-kw-peak-three-phase-commercial-string-inverter","provider":"Green Efficients Distro","version":"1.0","type":"link"}