{"product_id":"fronius-primo-208-240-v-6-6-12-7-kw-single-phase-string-inverter","title":"Fronius Primo 208-240 V 6.6-12.7 kW Single Phase String Inverter","description":"\u003cp\u003e\u003cspan\u003eThe Fronius Primo inverter series has been specially developed for the demands of the North American market. With power categories from 3.8 to 15 kW, the single-phase, transformerless device is the perfect inverter for private households. Its innovative SuperFlex Design provides maximum flexibility in system design, while the SnapINverter mounting system makes installation and maintenance as easy as possible. The communication package included as standard, with WLAN, energy management, several interfaces and much more besides, makes the Fronius Primo a communicative inverter for home owners. Standard equipment also includes a built-in arc detector (AFCI = Arc Fault Circuit Interrupter), in keeping with all other North American SnapINverters. With power categories ranging from 3.8 kW to 15.0 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnapINverter hinge mounting system, which allows for lightweight, secure, and convenient installation. The Fronius Primo has several integrated features that set it apart from competitors including dual power point trackers, high system voltage, a wide input voltage range, Wi-Fi and SunSpec Modbus interface, as well as Fronius' online and mobile monitoring platform Fronius Solar. Web.\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePC board replacement process\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSnapINverter mounting system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWi-Fi® interface\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesign Flexibility\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSnapINverter technology - The SnapINverter generation of inverters features a simple, standardized mounting system, making installation and maintenance easier than ever. A special feature in the design of the device is that the connection area is separate from the power stage set compartment, with both being installed separately. The remarkably light connection area and all its cabling is fitted to the wall first, followed by the power stage set. The innovative hinged system makes installation and servicing extremely user-friendly. The inverter is simply placed in the wall bracket and then secured. This means that it is not necessary to remove the entire inverter for servicing, just the power stage set. All the cabling remains in place\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated data communication - We are the first inverter manufacturer to offer a data communication package with fully integrated datalogging, WLAN, Ethernet, energy management, web server and a range of interfaces. The inverter is connected to the internet by network cable or WLAN - without additional cabling - and grants you the perfect overview of how the PV system is operating. Connection to third-party components is provided by means of interfaces such as Modbus TCP SunSpec, Modbus RTU SunSpec or Fronius Solar API (JSON). The open interfaces can also be operated in parallel to the Fronius Solar. Web\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuperFlex Design - The Fronius SuperFlex Design is an ingenious combination of technical performance attributes that make designing your PV system not only extremely simple, but also incredibly flexible. The key performance factors of the SuperFlex Design are two MPP trackers, together with a high system voltage and wide DC input voltage range. Every DC input, and therefore every MPP tracker, is able to accommodate the entire nominal output of the inverter. Regardless of whether the inverter has to cope with different roof orientations, shading of one or two strings, or the use of residual modules: a Fronius inverter featuring integrated SuperFlex Design will satisfy every conceivable operational PV system planning scenario using just a single inverter model\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmart Grid Ready - Fronius inverters are ready for the Smart Grid of tomorrow. The inverters are optimally equipped to meet the technical requirements of grids in the future. A series of smart functions, known as Advanced Grid Features, are built into the devices. They include a number of control functions for optimum feed-in of reactive power and effective power. These functions are designed to enable stable grid operation even when the PV system density is very high and to prevent unwanted interruptions to feed-in and associated yield losses if grid parameters exceed the thresholds. Fronius inverters therefore help to guarantee the yield of a PV system. Furthermore, where feed-in limits are imposed, Fronius inverters can provide dynamic feed-in control with self-consumption taken into account. Just connect the meter and set the feed-in limit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eArc Fault Circuit Interruption Integrated - The Fronius Arc Fault Circuit Interruption (AFCI) makes each inverter NEC 2011 compliant and maintains some of the most civilized, integrated technology available today. Ensuring the utmost safety, AFCI shuts down the inverter in the event of an arc fault\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eActive Cooling - Active cooling technology relies on one or more fans, which not only avoid hot spots, but also regulate the air circulation inside the inverter, thus keeping the temperature of the power electronics low. This has a positive effect on the service life of the devices, optimizes yields and reduces costs. At Fronius, active cooling is supplied as standard in all devices\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUSB (A socket) - Datalogging and inverter update possible via USB, 2x RS422 (RJ45 socket) - Fronius Solar Net, interface protocol, Wi-fi\/Ethernet LAN - Wireless standard 802.1 1 b\/g\/n\/Fronius Solar. Web, SunSpec Modbus TCP, JSON, Datalogger and Webserver included, Serial RS485 - SunSpec Modbus RTU or meter connection, 6 inputs or 4 digital inputs\/outputs - Load management; signaling, multipurpose I\/O\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdmissible conductor size DC - AWG 14 - AWG 6 copper (solid\/stranded\/fine stranded) (AWG 10 copper or AWG 8 aluminum for overcurrent protective devices up to 60 A, from 61 to 100 A minimum AWG 8 for copper or AWG 6 aluminum has to be used), AWG 6 - AWG 2 copper (solid\/stranded) Multi Contact Wiring able with AWG 12\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAdmissible conductor size AC - AWG 14 - AWG 6\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"0\" data-end=\"22\"\u003e\n\u003cstrong data-start=\"2\" data-end=\"12\" data-is-only-node=\"\"\u003eWidth:\u003c\/strong\u003e 16.9 in\u003c\/li\u003e\n\u003cli data-start=\"23\" data-end=\"46\"\u003e\n\u003cstrong data-start=\"25\" data-end=\"36\" data-is-only-node=\"\"\u003eHeight:\u003c\/strong\u003e 24.7 in\u003c\/li\u003e\n\u003cli data-start=\"47\" data-end=\"68\"\u003e\n\u003cstrong data-start=\"49\" data-end=\"59\" data-is-only-node=\"\"\u003eDepth:\u003c\/strong\u003e 8.1 in\u003c\/li\u003e\n\u003cli data-start=\"69\" data-end=\"116\"\u003e\n\u003cstrong data-start=\"71\" data-end=\"102\" data-is-only-node=\"\"\u003eRecommended PV Power (kWp):\u003c\/strong\u003e 6.6-12.7 kW\u003c\/li\u003e\n\u003cli data-start=\"117\" data-end=\"180\"\u003e\n\u003cstrong data-start=\"119\" data-end=\"168\" data-is-only-node=\"\"\u003eMaximum Usable Input Current (MPPT 1\/MPPT 2):\u003c\/strong\u003e 18 A\/18 A\u003c\/li\u003e\n\u003cli data-start=\"181\" data-end=\"239\"\u003e\n\u003cstrong data-start=\"183\" data-end=\"232\" data-is-only-node=\"\"\u003eMaximum Usable Input Current (MPPT 1+MPPT 2):\u003c\/strong\u003e 36 A\u003c\/li\u003e\n\u003cli data-start=\"240\" data-end=\"317\"\u003e\n\u003cstrong data-start=\"242\" data-end=\"307\" data-is-only-node=\"\"\u003eMaximum Array Short-Circuit Current (1.5 lmax) (MPPT1\/MPPT2):\u003c\/strong\u003e 27\/27 A\u003c\/li\u003e\n\u003cli data-start=\"318\" data-end=\"354\"\u003e\n\u003cstrong data-start=\"320\" data-end=\"346\" data-is-only-node=\"\"\u003eNominal Input Voltage:\u003c\/strong\u003e 420 V\u003c\/li\u003e\n\u003cli data-start=\"355\" data-end=\"390\"\u003e\n\u003cstrong data-start=\"357\" data-end=\"379\" data-is-only-node=\"\"\u003eOperating Voltage:\u003c\/strong\u003e 80-600 V\u003c\/li\u003e\n\u003cli data-start=\"391\" data-end=\"423\"\u003e\n\u003cstrong data-start=\"393\" data-end=\"416\" data-is-only-node=\"\"\u003eDC Startup Voltage:\u003c\/strong\u003e 80 V\u003c\/li\u003e\n\u003cli data-start=\"424\" data-end=\"460\"\u003e\n\u003cstrong data-start=\"426\" data-end=\"448\" data-is-only-node=\"\"\u003eMPP Voltage Range:\u003c\/strong\u003e 270-480 V\u003c\/li\u003e\n\u003cli data-start=\"461\" data-end=\"497\"\u003e\n\u003cstrong data-start=\"463\" data-end=\"489\" data-is-only-node=\"\"\u003eMaximum Input Voltage:\u003c\/strong\u003e 600 V\u003c\/li\u003e\n\u003cli data-start=\"498\" data-end=\"523\"\u003e\n\u003cstrong data-start=\"500\" data-end=\"519\" data-is-only-node=\"\"\u003eNumber of MPPT:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli data-start=\"524\" data-end=\"589\"\u003e\n\u003cstrong data-start=\"526\" data-end=\"551\" data-is-only-node=\"\"\u003eMaximum Output Power:\u003c\/strong\u003e 7900 VA at 208 V \/ 8200 VA at 240 V\u003c\/li\u003e\n\u003cli data-start=\"590\" data-end=\"629\"\u003e\n\u003cstrong data-start=\"592\" data-end=\"617\" data-is-only-node=\"\"\u003eOutput Configuration:\u003c\/strong\u003e 208\/240 V\u003c\/li\u003e\n\u003cli data-start=\"630\" data-end=\"687\"\u003e\n\u003cstrong data-start=\"632\" data-end=\"665\" data-is-only-node=\"\"\u003eFrequency Range (Adjustable):\u003c\/strong\u003e 45-55 Hz \/ 50-66 Hz\u003c\/li\u003e\n\u003cli data-start=\"688\" data-end=\"758\"\u003e\n\u003cstrong data-start=\"690\" data-end=\"743\" data-is-only-node=\"\"\u003eOperating Frequency Range Default for CAL Setups:\u003c\/strong\u003e 58.5-60.5 Hz\u003c\/li\u003e\n\u003cli data-start=\"759\" data-end=\"826\"\u003e\n\u003cstrong data-start=\"761\" data-end=\"813\" data-is-only-node=\"\"\u003eOperating Frequency Range Default for HI Setups:\u003c\/strong\u003e 57-60.5 Hz\u003c\/li\u003e\n\u003cli data-start=\"827\" data-end=\"869\"\u003e\n\u003cstrong data-start=\"829\" data-end=\"861\" data-is-only-node=\"\"\u003eNominal Operating Frequency:\u003c\/strong\u003e 60 Hz\u003c\/li\u003e\n\u003cli data-start=\"870\" data-end=\"914\"\u003e\n\u003cstrong data-start=\"872\" data-end=\"908\" data-is-only-node=\"\"\u003eTotal Harmonic Distortion (THD):\u003c\/strong\u003e \u0026lt;5%\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"957\"\u003e\n\u003cstrong data-start=\"917\" data-end=\"940\" data-is-only-node=\"\"\u003ePower Factor Range:\u003c\/strong\u003e 0.85-1 Ind\/Cap\u003c\/li\u003e\n\u003cli data-start=\"958\" data-end=\"1032\"\u003e\n\u003cstrong data-start=\"960\" data-end=\"998\" data-is-only-node=\"\"\u003eMaximum Continuous Output Current:\u003c\/strong\u003e 38 A at 208 V \/ 34.2 A at 240 V\u003c\/li\u003e\n\u003cli data-start=\"1033\" data-end=\"1091\"\u003e\n\u003cstrong data-start=\"1035\" data-end=\"1060\" data-is-only-node=\"\"\u003eOCPD\/AC Breaker Size:\u003c\/strong\u003e 50 A at 208 V, 45 A at 240 V\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1123\"\u003e\n\u003cstrong data-start=\"1094\" data-end=\"1117\" data-is-only-node=\"\"\u003eMaximum Efficiency:\u003c\/strong\u003e 97%\u003c\/li\u003e\n\u003cli data-start=\"1124\" data-end=\"1153\"\u003e\n\u003cstrong data-start=\"1126\" data-end=\"1145\" data-is-only-node=\"\"\u003eCEC Efficiency:\u003c\/strong\u003e 96.5%\u003c\/li\u003e\n\u003cli data-start=\"1154\" data-end=\"1187\"\u003e\n\u003cstrong data-start=\"1156\" data-end=\"1177\" data-is-only-node=\"\"\u003eEnclosure Rating:\u003c\/strong\u003e NEMA 4X\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1224\"\u003e\n\u003cstrong data-start=\"1190\" data-end=\"1217\" data-is-only-node=\"\"\u003eNight Time Consumption:\u003c\/strong\u003e \u0026lt;1 W\u003c\/li\u003e\n\u003cli data-start=\"1225\" data-end=\"1267\"\u003e\n\u003cstrong data-start=\"1227\" data-end=\"1249\" data-is-only-node=\"\"\u003eInverter Topology:\u003c\/strong\u003e Transformerless\u003c\/li\u003e\n\u003cli data-start=\"1268\" data-end=\"1303\"\u003e\n\u003cstrong data-start=\"1270\" data-end=\"1282\" data-is-only-node=\"\"\u003eCooling:\u003c\/strong\u003e Variable Speed Fan\u003c\/li\u003e\n\u003cli data-start=\"1304\" data-end=\"1342\"\u003e\n\u003cstrong data-start=\"1306\" data-end=\"1323\" data-is-only-node=\"\"\u003eInstallation:\u003c\/strong\u003e Indoor \u0026amp; Outdoor\u003c\/li\u003e\n\u003cli data-start=\"1343\" data-end=\"1386\"\u003e\n\u003cstrong data-start=\"1345\" data-end=\"1371\" data-is-only-node=\"\"\u003eOperating Temperature:\u003c\/strong\u003e -40 to 131°F\u003c\/li\u003e\n\u003cli data-start=\"1387\" data-end=\"1411\"\u003e\n\u003cstrong data-start=\"1389\" data-end=\"1402\" data-is-only-node=\"\"\u003eHumidity:\u003c\/strong\u003e 0-100%\u003c\/li\u003e\n\u003cli data-start=\"1412\" data-end=\"1437\"\u003e\n\u003cstrong data-start=\"1414\" data-end=\"1428\" data-is-only-node=\"\"\u003eElevation:\u003c\/strong\u003e 4000 m\u003c\/li\u003e\n\u003cli data-start=\"1438\" data-end=\"1573\"\u003e\n\u003cstrong data-start=\"1440\" data-end=\"1468\" data-is-only-node=\"\"\u003eDC Connection Terminals:\u003c\/strong\u003e 4x DC+ \u0026amp; 4x DC- Screw Terminals for Copper (Solid\/Stranded\/Fine Stranded) or Aluminum (Solid\/Stranded)\u003c\/li\u003e\n\u003cli data-start=\"1574\" data-end=\"1631\"\u003e\n\u003cstrong data-start=\"1576\" data-end=\"1604\" data-is-only-node=\"\"\u003eAC Connection Terminals:\u003c\/strong\u003e Screw Terminals 12-6 AWG\u003c\/li\u003e\n\u003cli data-start=\"1632\" data-end=\"1675\"\u003e\n\u003cstrong data-start=\"1634\" data-end=\"1669\" data-is-only-node=\"\"\u003eDC Reverse Polarity Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1676\" data-end=\"1771\"\u003e\n\u003cstrong data-start=\"1678\" data-end=\"1697\" data-is-only-node=\"\"\u003eAnti-Islanding:\u003c\/strong\u003e Internal, In Accordance with UL 1741-2016-09, IEEE 1547-2003 \u0026amp; NEC 2017\u003c\/li\u003e\n\u003cli data-start=\"1772\" data-end=\"1845\"\u003e\n\u003cstrong data-start=\"1774\" data-end=\"1806\" data-is-only-node=\"\"\u003eOver Temperature Protection:\u003c\/strong\u003e Output Power Derating\/Active Cooling\u003c\/li\u003e\n\u003cli data-start=\"1846\" data-end=\"1863\"\u003e\n\u003cstrong data-start=\"1848\" data-end=\"1857\" data-is-only-node=\"\"\u003eAFCI:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1864\" data-end=\"1902\"\u003e\n\u003cstrong data-start=\"1866\" data-end=\"1896\" data-is-only-node=\"\"\u003eRapid Shutdown Compliance:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1903\" data-end=\"1974\"\u003e\n\u003cstrong data-start=\"1905\" data-end=\"1968\" data-is-only-node=\"\"\u003eGround Fault Protection with Isolation Monitor Interrupter:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"1975\" data-end=\"2001\"\u003e\n\u003cstrong data-start=\"1977\" data-end=\"1995\" data-is-only-node=\"\"\u003eDC Disconnect:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2156\"\u003e\n\u003cstrong data-start=\"2004\" data-end=\"2019\" data-is-only-node=\"\"\u003eInterfaces:\u003c\/strong\u003e USB (A Socket), 2x RS422 (RJ45 Socket), Wi-Fi\/Ethernet LAN, Datalogger \u0026amp; Webserver, Serial RS485, 6 Inputs or 4 Digital Inputs\/Outputs\u003c\/li\u003e\n\u003cli data-start=\"2157\" data-end=\"2533\"\u003e\n\u003cstrong data-start=\"2159\" data-end=\"2173\" data-is-only-node=\"\"\u003eStandards:\u003c\/strong\u003e\n\u003cul data-start=\"2178\" data-end=\"2533\"\u003e\n\u003cli data-start=\"2178\" data-end=\"2269\"\u003eUL 1741-2010 Second Edition (Incl. UL1741 Supplement SA 2016-09 for California Rule 21)\u003c\/li\u003e\n\u003cli data-start=\"2272\" data-end=\"2333\"\u003eUL1998 (for functions: AFCI, RCMU \u0026amp; Isolation Monitoring)\u003c\/li\u003e\n\u003cli data-start=\"2336\" data-end=\"2372\"\u003eIEEE 1547-2003, IEEE 1547.1-2003\u003c\/li\u003e\n\u003cli data-start=\"2375\" data-end=\"2395\"\u003eANSI\/IEEE C62.41\u003c\/li\u003e\n\u003cli data-start=\"2398\" data-end=\"2419\"\u003eFCC Part 15 A \u0026amp; B\u003c\/li\u003e\n\u003cli data-start=\"2422\" data-end=\"2446\"\u003eNEC 2017 Article 690\u003c\/li\u003e\n\u003cli data-start=\"2449\" data-end=\"2471\"\u003eC22.2 No. 107.1-16\u003c\/li\u003e\n\u003cli data-start=\"2474\" data-end=\"2499\"\u003eUL1699B Issue 2 -2013\u003c\/li\u003e\n\u003cli data-start=\"2502\" data-end=\"2533\"\u003eCSA TIL M-07 Issue 1 - 2013\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2534\" data-end=\"2560\"\u003e\n\u003cstrong data-start=\"2536\" data-end=\"2549\" data-is-only-node=\"\"\u003eWarranty:\u003c\/strong\u003e 10 Years\u003c\/li\u003e\n\u003cli data-start=\"2561\" data-end=\"2585\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"2563\" data-end=\"2574\" data-is-only-node=\"\"\u003eWeight:\u003c\/strong\u003e 47.29 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDocuments \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/store.solarcellzusa.com\/Item%20Documents\/FRO-P-10.0-1-208-240_Specification%20Sheet.pdf\" style=\"color: rgb(255, 42, 0);\" target=\"_blank\"\u003eSpecification Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/store.solarcellzusa.com\/Item%20Documents\/FRO-P-10.0-1-208-240_Instruction_Installation%20Manual.pdf\" style=\"color: rgb(255, 42, 0);\" target=\"_blank\"\u003eInstruction\/Installation Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/store.solarcellzusa.com\/Item%20Documents\/FRO-P-10.0-1-208-240_Warranty%20Information.pdf\" style=\"color: rgb(255, 42, 0);\" target=\"_blank\"\u003eWarranty Information\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fronius","offers":[{"title":"Default Title","offer_id":47568654172343,"sku":"FRO-P-8.2-1-208-240","price":1926.72,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0740\/8078\/0471\/files\/FRO-P-5.0-1-208-240-L_01_e3c16ef4-5319-4b42-833b-7ec510271c7d.jpg?v=1776066862","url":"https:\/\/greenefficientdistro.com\/products\/fronius-primo-208-240-v-6-6-12-7-kw-single-phase-string-inverter","provider":"Green Efficients Distro","version":"1.0","type":"link"}